Index of /arm-iop-file/2022/hou/tracer-tamu/brooks-ccn

[ICO]NameLast modifiedSizeDescription

[PARENTDIR]Parent Directory  -  
[TXT]ARM0763.tracer_tamu_220823_ccn.20230505_14_05_39.csv2023-05-15 13:50 322K 
[TXT]ARM0763.tracer_tamu_220831_ccn.20230505_14_05_47.csv2023-05-15 13:50 51K 
[TXT]ARM0763.tracer_tamu_220818_ccn.20230505_14_05_35.csv2023-05-15 13:50 189K 
[TXT]ARM0763.tracer_tamu_220828_ccn.20230505_14_05_46.csv2023-05-15 13:50 224K 
[TXT]ARM0763.tracer_tamu_220728_ccn.20230505_14_05_26.csv2023-05-15 13:50 94K 
[TXT]ARM0763.tracer_tamu_220713_ccn.20230505_14_05_997.csv2023-05-15 13:50 122K 
[TXT]ARM0763.tracer_tamu_220906_ccn.20230505_14_05_50.csv2023-05-15 13:50 191K 
[TXT]ARM0763.tracer_tamu_220824_ccn.20230505_14_05_41.csv2023-05-15 13:50 151K 
[TXT]ARM0763.tracer_tamu_220917_ccn.20230505_14_05_55.csv2023-05-15 13:50 135K 
[TXT]ARM0763.tracer_tamu_220923_ccn.20230505_14_05_63.csv2023-05-15 13:50 270K 
[TXT]ARM0763.tracer_tamu_220919_ccn.20230505_14_05_58.csv2023-05-15 13:50 148K 
[TXT]ARM0763.tracer_tamu_220922_ccn.20230505_14_05_61.csv2023-05-15 13:50 276K 
[TXT]ARM0763.tracer_tamu_220722_ccn.20230505_14_05_21.csv2023-05-15 13:50 130K 
[TXT]ARM0763.tracer_tamu_220826_ccn.20230505_14_05_43.csv2023-05-15 13:50 186K 
[TXT]ARM0763.tracer_tamu_220726_ccn.20230505_14_05_23.csv2023-05-15 13:50 242K 
[TXT]ARM0763.tracer_tamu_220925_ccn.20230505_14_05_64.csv2023-05-15 13:50 218K 
[TXT]ARM0763.tracer_tamu_220907_ccn.20230505_14_05_52.csv2023-05-15 13:50 239K 
[TXT]ARM0763.tracer_tamu_220901_ccn.20230505_14_05_49.csv2023-05-15 13:50 155K 
[TXT]ARM0763.tracer_tamu_220921_ccn.20230505_14_05_59.csv2023-05-15 13:50 274K 
[TXT]ARM0763.tracer_tamu_220730_ccn.20230505_14_05_29.csv2023-05-15 13:50 183K 
[TXT]ARM0763.tracer_tamu_220808_ccn.20230505_14_05_30.csv2023-05-15 13:50 176K 
[TXT]ARM0763.tracer_tamu_220720_ccn.20230505_14_05_20.csv2023-05-15 13:50 212K 
[TXT]ARM0763.tracer_tamu_220809_ccn.20230505_14_05_32.csv2023-05-15 13:50 179K 
[TXT]ARM0763.tracer_tamu_220810_ccn.20230505_14_05_33.csv2023-05-15 13:50 260K 
[TXT]ARM0763.tracer_tamu_220729_ccn.20230505_14_05_27.csv2023-05-15 13:50 146K 
[TXT]ARM0763.tracer_tamu_220821_ccn.20230505_14_05_36.csv2023-05-15 13:50 183K 
[TXT]ARM0763.tracer_tamu_220822_ccn.20230505_14_05_38.csv2023-05-15 13:50 128K 
[TXT]ARM0763.tracer_tamu_220909_ccn.20230505_14_05_53.csv2023-05-15 13:50 193K 
[TXT]ARM0763.tracer_tamu_220918_ccn.20230505_14_05_56.csv2023-05-15 13:50 121K 
[TXT]ARM0763.tracer_tamu_220727_ccn.20230505_14_05_24.csv2023-05-15 13:50 113K 
[TXT]ARM0763.tracer_tamu_220827_ccn.20230505_14_05_44.csv2023-05-15 13:50 249K 

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

Overview:

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”.

Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution.  

The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance.  

This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu.

Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008.

Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014.

Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991.

Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948.

Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011.

Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

Metadata Creator:
Name: Seth Allen Thompson
Email: sthomp14@tamu.edu Phone: 3014017690
Street: 3150 TAMU City: College Station
State: TX Postal: 77843
Contact Info:
Name: Sarah D. Brooks
Email: sbrooks@tamu.edu Phone:
Street: 3150 TAMU City: College Station
State: TX Postal: 77843
Investigator(s): Sarah Brooks (sbrooks@tamu.edu) 0000-0001-8185-9332
Seth Thompson (sthomp14@tamu.edu) 0000-0003-2343-6993
Data Citation:https://doi.org/10.5439/1972179
Data Format:csv
File Naming Convention:tracer_tamu_YYMMDD_ccn.csv, where YY = Year, MM = Month, DD = Day
Abstract:

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”.

Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution.  

The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance.  

This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu.

Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008.

Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014.

Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991.

Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948.

Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011.

Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

Data Usage:The columns within each datafile are as follows: Time (date and time in UTC, format: yyyy/mm/dd hh:mm:ss), Location (general location of measurement), Latitude (in degrees), Longitude (in degrees), SS (current supersaturation in %), and N_CCN (ccn number concentration in #/cm3).
Data Credit:DOE ASR grant DE-SC0021047 (PI: Anita Rapp)
Arm Sites: hou
Content Time Range: Begin: 2022-07-13 End: 2022-09-25
Instrument(s):Cloud Condensation Nuclei Particle Counter
Data Type:TAMU Mobile Facility Measurements during TRACER
Scientific Measurements(s):
Measurement nameVariables
Number concentration of CCN
Stratum Keyword(s):
Atmosphere: Troposphere
Data Quality:
Attribute Accuracy: No formal uncertainty assessments were conducted and no estimates of uncertainty are reported.
Positional Accuracy: The location column was assigned to provide a general location for the measurement according to our sampling site's street address. Positional information (Latitude and Longitude columns) was obtained using cell phone application, "My Altitude", GPS coordinates.
Consistency and Completeness Report: Data set is considered complete for the information presented, as described in the abstract. Users are advised to read the rest of the metadata record carefully for additional details.
Use Restrictions: No use constraints are associated with this data.
Distribution Info:
Organization Name: ARM Archive User Services
Email: armarchive[at]ornl.gov Phone: 1-888-ARM-DATA
Street: Oak Ridge National Laboratory City: Oak Ridge
State: Tennessee Postal: 37831-6290