Index of /arm-iop-file/2022/hou/tracer-tamu/brooks-cpc

[ICO]NameLast modifiedSizeDescription

[PARENTDIR]Parent Directory  -  
[TXT]ARM0761.tracer_tamu_220922_cpc.20230505_13_05_187.csv2023-05-12 19:54 1.4M 
[TXT]ARM0761.tracer_tamu_220823_cpc.20230505_13_05_144.csv2023-05-12 19:54 1.4M 
[TXT]ARM0761.tracer_tamu_220810_cpc.20230505_13_05_131.csv2023-05-12 19:54 1.4M 
[TXT]ARM0761.tracer_tamu_220923_cpc.20230505_13_05_192.csv2023-05-12 19:54 1.4M 
[TXT]ARM0761.tracer_tamu_220921_cpc.20230505_13_05_183.csv2023-05-12 19:54 1.4M 
[TXT]ARM0761.tracer_tamu_220827_cpc.20230505_13_05_154.csv2023-05-12 19:54 1.1M 
[TXT]ARM0761.tracer_tamu_220720_cpc.20230505_13_05_107.csv2023-05-12 19:54 1.1M 
[TXT]ARM0761.tracer_tamu_220907_cpc.20230505_13_05_169.csv2023-05-12 19:54 1.0M 
[TXT]ARM0761.tracer_tamu_220818_cpc.20230505_13_05_136.csv2023-05-12 19:54 1.0M 
[TXT]ARM0761.tracer_tamu_220901_cpc.20230505_13_05_163.csv2023-05-12 19:54 1.0M 
[TXT]ARM0761.tracer_tamu_220713_cpc.20230505_13_05_79.csv2023-05-12 19:54 962K 
[TXT]ARM0761.tracer_tamu_220925_cpc.20230505_13_05_197.csv2023-05-12 19:54 944K 
[TXT]ARM0761.tracer_tamu_220809_cpc.20230505_13_05_127.csv2023-05-12 19:54 856K 
[TXT]ARM0761.tracer_tamu_220909_cpc.20230505_13_05_173.csv2023-05-12 19:54 853K 
[TXT]ARM0761.tracer_tamu_220906_cpc.20230505_13_05_166.csv2023-05-12 19:54 828K 
[TXT]ARM0761.tracer_tamu_220821_cpc.20230505_13_05_139.csv2023-05-12 19:54 816K 
[TXT]ARM0761.tracer_tamu_220808_cpc.20230505_13_05_124.csv2023-05-12 19:54 816K 
[TXT]ARM0761.tracer_tamu_220730_cpc.20230505_13_05_121.csv2023-05-12 19:54 814K 
[TXT]ARM0761.tracer_tamu_220826_cpc.20230505_13_05_151.csv2023-05-12 19:54 797K 
[TXT]ARM0761.tracer_tamu_220828_cpc.20230505_13_05_158.csv2023-05-12 19:54 791K 
[TXT]ARM0761.tracer_tamu_220919_cpc.20230505_13_05_180.csv2023-05-12 19:54 688K 
[TXT]ARM0761.tracer_tamu_220726_cpc.20230505_13_05_112.csv2023-05-12 19:54 636K 
[TXT]ARM0761.tracer_tamu_220729_cpc.20230505_13_05_119.csv2023-05-12 19:54 621K 
[TXT]ARM0761.tracer_tamu_220918_cpc.20230505_13_05_178.csv2023-05-12 19:54 571K 
[TXT]ARM0761.tracer_tamu_220822_cpc.20230505_13_05_142.csv2023-05-12 19:54 566K 
[TXT]ARM0761.tracer_tamu_220917_cpc.20230505_13_05_175.csv2023-05-12 19:54 520K 
[TXT]ARM0761.tracer_tamu_220727_cpc.20230505_13_05_115.csv2023-05-12 19:54 498K 
[TXT]ARM0761.tracer_tamu_220728_cpc.20230505_13_05_117.csv2023-05-12 19:54 490K 
[TXT]ARM0761.tracer_tamu_220831_cpc.20230505_13_05_161.csv2023-05-12 19:54 446K 
[TXT]ARM0761.tracer_tamu_220824_cpc.20230505_13_05_149.csv2023-05-12 19:54 339K 
[TXT]ARM0761.tracer_tamu_220722_cpc.20230505_13_05_111.csv2023-05-12 19:54 199K 

CPC data from TAMU TRACER campaign in the Houston, TX region from July to September 2022

Overview:

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”.

Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.3 LPM is directed to the CPC. To correct the data for particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate total particle loss through the inlet for every SMPS scan at a single deployment location. Second, the CPC data was corrected for particle losses using the average of the total losses per scan. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. An additional flatline correction of 14% was applied to all CPC data based on laboratory calibration prior to and after the campaign. In laboratory calibrations, we identified that for the same sample of air the field CPC (GRIMM Model 5.403 CPC) undercounted the total concentration of particles by 14% compared to the ground truth laboratory CPC (TSI Model 3750).

This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu.

Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991.

Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948.

Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011.

Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

Metadata Creator:
Name: Seth Allen Thompson
Email: sthomp14@tamu.edu Phone: 3014017690
Street: 3150 TAMU City: College Station
State: TX Postal: 77843
Contact Info:
Name: Sarah D. Brooks
Email: sbrooks@tamu.edu Phone:
Street: 3150 TAMU City: College Station
State: TX Postal: 77843
Investigator(s): Sarah Brooks (sbrooks@tamu.edu) 0000-0001-8185-9332
Seth Thompson (sthomp14@tamu.edu) 0000-0003-2343-6993
Data Citation:https://doi.org/10.5439/1971998
Data Format:csv
File Naming Convention:tracer_tamu_YYMMDD_cpc.csv, where YY = Year, MM = Month, DD = Day
Abstract:

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”.

Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.3 LPM is directed to the CPC. To correct the data for particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate total particle loss through the inlet for every SMPS scan at a single deployment location. Second, the CPC data was corrected for particle losses using the average of the total losses per scan. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. An additional flatline correction of 14% was applied to all CPC data based on laboratory calibration prior to and after the campaign. In laboratory calibrations, we identified that for the same sample of air the field CPC (GRIMM Model 5.403 CPC) undercounted the total concentration of particles by 14% compared to the ground truth laboratory CPC (TSI Model 3750).

This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu.

Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991.

Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948.

Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011.

Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

Data Usage:The columns within each datafile are as follows: Time (date and time in UTC, format: yyyy/mm/dd hh:mm:ss), Location (general location of measurement), Latitude (in degrees), Longitude (in degrees), and concentration (particle number concentration in #/cm3).
Data Credit:DOE ASR grant DE-SC0021047 (PI: Anita Rapp)
Arm Sites: hou
Content Time Range: Begin: 2022-07-13 End: 2022-09-25
Instrument(s):Condensation Particle Counter
Data Type:TAMU Mobile Facility Measurements during TRACER
Scientific Measurements(s):
Measurement nameVariables
Total number concentration
Stratum Keyword(s):
Atmosphere: Troposphere
Data Quality:
Attribute Accuracy: No formal uncertainty assessments were conducted and no estimates of uncertainty are reported.
Positional Accuracy: The location column was assigned to provide a general location for the measurement according to our sampling site's street address. Positional information (Latitude and Longitude columns) was obtained using cell phone GPS coordinates.
Consistency and Completeness Report: Data set is considered complete for the information presented, as described in the abstract. Users are advised to read the rest of the metadata record carefully for additional details.
Use Restrictions: No use constraints are associated with this data.
Distribution Info:
Organization Name: ARM Archive User Services
Email: armarchive[at]ornl.gov Phone: 1-888-ARM-DATA
Street: Oak Ridge National Laboratory City: Oak Ridge
State: Tennessee Postal: 37831-6290